INPUT / OUTPUT: 8 digital inputs, 8 PNP outputs;
OUTPUT / INPUT: RS485 - Modbus Slave (ASCII, RTU) ;
Up to 128 modules on RS485 network;
Mounting on a DIN rail;
8 configurable 32-bit counters;
Inputs PNP or NPN, depending on the...
INPUT: 8 universal analogue inputs;
OUTPUT: RS485 - Modbus Slave (ASCII, RTU);
2 x configurable NPN outputs to 500mA, switched remotely or automatically when the set value is exceeded;
Mounting on a DIN rail;
voltage input: 0~10VDC;...
INPUT: 6 inputs for the temperature measurment;
OUTPUT: RS485 - Modbus Slave(ASCII, RTU);
2 x configurable NPN outputs to 500mA, switched remotely or automatically when the temperature is exceeded;
Support resistive thermometers: PT100,...
OUTPUT: 6 digital relay PNP;
INPUT: RS485 - Modbus Slave (ASCII, RTU) ;
Up to 128 modules on RS485 network;
Mounting on a DIN rail;
Max load 5A 250VAC; 10A 24VDC;
Changeover contacts;
Watchdog function;
Comfortable connectors...
OUTPUT: 4 digital outputs
INPUT: RS485 - Modbus Slave (ASCII, RTU)
Up to 128 modules on RS485 network
Mounting on a DIN rail
Outputs type PNP, 250mA
Watchdog function
Configuration: Modbus Configurator (free)
2 years guarantee...
INPUT: 4 digital inputs;
OUTPUT: RS485 - Modbus Slave (ASCII, RTU);
Up to 128 modules on RS485 network;
4 configurable 32-bit counters;
FRAM - non-volatile random-access memory;
Comfortable connectors for cables (up to 2.5 mm2);...
INPUT: 4 digital inputs;
OUTPUT: RS485 - Modbus Slave (ASCII, RTU);
Up to 128 modules on RS485 network;
Mounting on a DIN rail;
4 configurable 32-bit counters;
Inputs PNP or NPN, depending on the connection;
Comfortable...
INPUT/OUTPUT: 2 digital inputs / 2 digital outputs
OUTPUT/INPUT: RS485 - Modbus Slave (ASCII, RTU);
Up to 128 modules on RS485 network;
Mounting on a DIN rail;
2 configurable 32-bit counters;
Inputs PNP or NPN, depending on the...
INPUT: 1 input for the temperature measurment;
OUTPUT: RS485 - Modbus (ASCII, RTU);
1 configurable PNP or NPN output to 250mA, switched remotely or automatically when the temperature is exceeded;
Support resistive thermometers: PT100,...
OUTPUT: 1 current analog output 0~20mA or 4~20mA, 1 voltage analog output 0~10VDC,
INPUT: RS485 - Modbus Slave (ASCII, RTU);
Up to 128 modules on RS485 network;
2 digital inputs PNP or NPN types;
2 configurable 32-bit counters;
2...
INPUT: 1 x voltage analog input, 1 x current analog input;
OUTPUT: RS485 - Modbus Slave (ASCII, RTU);
Support voltage analog input: 0~10VDC; -10~+10VDC, 0~1VDC; -1~+1VDC
Support current analog input: 0~20mA, 4-20mA, -20~+20mA...
OUTPUT: 16 digital relay PNP;
INPUT: RS485 - Modbus Slave (ASCII, RTU);
Up to 128 modules on RS485 network;
Mounting on a DIN rail;
Max load 3A/COM 250VAC; 3A/COM 30VDC;
Watchdog function;
Comfortable connectors for cables (up...
OUTPUT: 16 digital outputs PNP;
INPUT: RS485 - Modbus Slave (ASCII, RTU);
Up to 128 modules on RS485 network;
Mounting on a DIN rail;
Output type PNP, 500mA;
Galvanic isolation of outputs;
Watchdog function;
Comfortable...
INPUT: 16 digital inputs;
OUTPUT: RS485 - Modbus Slave (ASCII, RTU);
Up to 128 modules on RS485 network;
FRAM - non-volatile random-access memory;
Mounting on a DIN rail;
16 configurable 32-bit counters;
Inputs PNP or NPN,...
INPUT: 16 digital inputs;
OUTPUT: RS485 - Modbus Slave (ASCII, RTU);
Up to 128 modules on RS485 network;
Mounting on a DIN rail;
16 configurable 32-bit counters;
Inputs PNP or NPN, depending on the connection;
Comfortable...
Inverter type: LV0015G100-4E0FN
Output Power Rating: 1,5 kW
Input Power Rating: 3-Phase, 400 V AC, 50/60 Hz
Output current, normal load/heavy load: 5,1A/4,0A
Output voltage: 3 x 400 V AC
Control method: V/F, Slip Compensation,...
Inverter type: LV0008G100-4E0FN
Output Power Rating: 0,75 kW
Input Power Rating: 3-Phase, 400 V AC, 50/60 Hz
Output current, normal load/heavy load: 3,1A/2,5A
Output voltage: 3 x 400 V AC
Control method: V/F, Slip Compensation,...
Filter Fan LV700 blowing 230VAC Supply voltage: 230VAC 50/60Hz Air flow direction: Blowing External dimensions: 323 x 323mm Air flow with exhaust filter: 530m 3 / h
Filter Fan LV500 blowing 230VAC
Supply voltage: 230VAC 50/60Hz
Air flow direction: Blowing
External dimensions: 250 x 250mm
Air flow with exhaust filter: 235m 3 / h
Inverter type: LSLV0110S100-4EOFNM
Output Power Rating: 11 / 15 kW
Input Power Rating: 3-Phase, 400 V AC, 50/60 Hz
Output current: 24,0 A/ 30,0 A
Output voltage: 3 x 400 V AC
Output frequency: 0,1...400 Hz (0-300 Hz for vector...
Inverter type: LSLV0075S100-4EOFNM
Output Power Rating: 7,5 / 11 kW
Input Power Rating: 3-Phase, 400 V AC, 50/60 Hz
Output current: 16,0 A/ 23,0 A
Output voltage: 3 x 400 V AC
Output frequency: 0,1...400 Hz (0-300 Hz for vector...
Inverter type: LSLV0008M100-1EOFNA
Output Power Rating: 0,75 kW
Input Power Rating: 1-Phase, 230 V AC, 50/60 Hz
Output current: 4,2 A
Output voltage: 3 phases (3 x 230 V AC)
Control mode: U/f
Inverter type: LSLV0004M100-1EOFNA
Output Power Rating: 0,4 kW
Input Power Rating: 1-Phase, 230 V AC, 50/60 Hz
Output current: 2,4 A
Output voltage: 3 phases (3 x 230 V AC)
Control mode: U/f
JWT6011F thermostat (normally open): commonly used in the monitoring filter fans, heat exchangers or when the temperature exceeds the set value the closed circuit output signal.
Filter fan with filter, FKL series, external dimensions 148,5 x 148,5 mm, reversible. The air flow direction is changed by mechanically inverting the fan relative to the grille
nominal voltage: 24VDC, 24VAC 50/60Hz
safety relay single-channel
can be used for emergency stop and safety door monitoring
number of enable current paths according to IEC/EN 60204: 4
number of signaling path: 1
manufacturer:...
DOL 44R-33 is a capacitive relay sensor for detection of feed, grain and solids. Supply voltage: 90~265VAC/DC . Diameter 32mm (1 1/4"), smooth housing. Sensor is equipped with relay output 5A/250VAC. Additional is possible to set...